24 Volt 1/2" Gas Pipe Inlet 1/2"Gas Pipe Outlet Special Design Gas is Step Opening Intermittent Pilo

24 Volt 1/2
Code: GSVR8204C
Price: $196.87
Quantity in Basket: None
Quantity:
Honeywell Intermittent Pilot Dual Automatic Valve Combination Gas Controls.

Combination gas controls for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh.
Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.
Use with S86F,H; S8600F,H and S8610 Control Modules.

Natural Gas Only.

L.P.Gas Conversion Kit Located @ the bottom of this page

Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Standard and slow opening natural gas.
All adjustments and wiring connections are accessible from top of control.
ON-OFF lighting sequence.

Replaces Gas Valve Part Numbers:

025-25424-000 VR8204C 3007 025-25424-700 02525424700 VR8204C3007 025-21704-000 VR8204C-1084 VR8204 VR844P1181 VR8204C VR8204C1092 VR8204C3007 VR8204C1134 VR8204P1015 VR8204C1001 VR8204C1019 VR8204C1084 025-37334-000 02537334000 CARVR8204C1019.

Used in Many Brands of Furnaces

Used in Coleman York Furnace Models:

P4USD12N06501A PCCU-LD12N105A PCCULD12N105A P3USD20N12001B PDCU-LD12N105A P3USD12N06501A P3CSD14N10501A P3CSD14N10501B PDCULD12N105A P2UXD10N10501A

Used in Burnham Models:

P-205PV-WNI

Product Specifications:

Ignition Type Intermittent Pilot.
Type of Gas Natural.
Inlet/Outlet Size (in.) 1/2 in. x 1/2 in.
Opening Characteristics (standard, step) Step Opening
Approvals AGA Design Certified: File No. L2025006; CSA Design Certified: File No. L2025006.
Dimensions (in.) 4 15/16 in. high, 4 1/8 in. wide, 2 11/16 in. deep.
Dimensions (mm) 125 mm high, 104 mm wide, 69 mm deep.
Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Body Pattern Straight-through with 1/2 in. inlets and outlets.
Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing.
Pressure Tapping 1/8 in. npt with plug.
Pressure Rating (psi) 1/2 psi.
Pressure Rating (kPa) 3.5 kPa.
Pressure Regulator Setting (psi) step: 0.9 in. wc; full rate 3.5 in. wc.
Pressure Regulator Setting (kPa) step: 0.22 kPa; full rate: 0.87 kPa.
Electrical Ratings (Vac) 24 Vac.
Frequency (Hz) 60 Hz.
Electrical Connections 1/4 in. male quick-connects.
Anticipator Setting 0.5 A.
Temperature Ratings (F) 0 F to 175 F.
Temperature Ratings (C) -18 F to +79 F