Two Rod Intermittent Pilot Control with continuous trial time and 15 second lockout timing (Honeywel

Two Rod Intermittent Pilot Control with continuous trial time and 15 second lockout timing (Honeywel
Code: IGM8620C13
Price: $187.88
Quantity in Basket: None
Quantity:
Two Rod Intermittent Pilot Control with continuous trial time and 15 second lockout timing (Honeywell)

Overview

Used with compatible valve and spark igniter to make an intermittent pilot ignition system for gas burners

Product Specifications

Description Provide electronic control of intermittent pilot ignition systems used on gas fired furnaces, boilers, and other heating appliances.
Ignition System Type Intermittent Pilot
Ignition Sequence Continous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
Typical Gas Control VR8204, VR8304
Type of Gas Natural or LP
Flame Sense Two Rods
Ignition Source Internal high voltage spark generator PrePurge None
Ignition Trials To Lockout continuous retry
Lockout Timing 15 sec. maximum
Ignition Trial Time (sec) continuous retry
Maximum Valve Load @ 24 Vac (Amps) 2A Pilot, 2A Main @ 155 F
Typical Ignition Hardware Q3452
Dimensions (in.) 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensions (mm) 100 mm high x 138 mm wide x 67 mm deep
Electrical Ratings 24 Vac
Frequency 60 Hz
Maximum Ambient Temperature (F) -40 F to +150 F
Maximum Ambient Temperature (C) -40 C to +74 C
Approvals, Canadian Standards Association Design Certified
Between Trial Time (sec) 5 minute delay after failed trial for ignition.
Flame Failure Response Time (sec) 0.8 sec. @1.0 mA flame current
Replaces Part Numbers: S8620C1003, CARS8620C1003.