Time Delay Compressor Short Cycle Protection Delay on Break Adj.180-600 seconds.

Time Delay Compressor Short Cycle Protection Delay on Break Adj.180-600 seconds.
Code: REL206A
Price: $63.33
Quantity in Basket: None
Quantity:
Universal Air Conditioning Time Delay Safety Switch.

Designed to protect air conditioning, refrigeration and heat pump equipment from damage which may be cause by short-cycling of Thermostat contacts:

Brownout Protection

Compressor lockout/anti-short cycle timer
Brownout protection
UL 873 recognition as compressor controller
Helps prevent scroll compressor reversal
Fixed ro adjustable timing
18-30 VAC

Compressor Time Delay Relay Specifications:

Input Control Voltage: 18-30
VAC Frequency: 50/60 Hz
Power Consumption: 2 watts max.
Timing Output Maximum Rating: 1.5
Amp Minimum Rating: 40m
AIn-Rush: 15 amps
Voltage Drop: 4.5
Maximum @ 1.5 amps
Leakage Current: 5mA maximum @ 240 VAC
Bypass Resistor: R1 to R2 <1K @ 24 VAC
Installation Instructions:

1.Disconnect Power
2.Connect terminals in series with the device.
3.Reapply power and check operation.

Timing Mode of Operation:

Upon application of power, the load is energized.

When the thermostat opens or there is a loss of power, the load is de-energized and the delay period begins.
The compressor will not start again during the delay period.

Replaces Time Delay Part Numbers:

EAC-426/4-180 1460-5001/B 1460-5001B 1C243 EAC100-3 STD 4011-3 1C-243 EAC-511 42-22655-01 RRGG-07E25JKR RAJB-030JAS ICM206 ICM-206 ICM206B P284-2390 4E235 BLPS24A2X600 CARICM206.

Used in Coleman York and many more air conditioning models:

4425A901