Electronic Ignition Control Module. (Robertshaw)

Electronic Ignition Control Module. (Robertshaw)
Code: IGM780845A
Price: $198.90
Quantity in Basket: None
Quantity:
New Upgraded Robertshaw Electronic Ignition Control Module:



Used in Bradford-White Water Heater :

MITW40L5LN10 MITW50l6CX10 MITW40L6CX10.

Used in A.O. Smith Water Heaters:

FPSE-75

Used in Modine Furnace Models:All (PD) Models and all (DB) Models.

This OEM Robertshaw Ignition Module is also used on many other brands of heating equipment.

Replaces Ignition Module Part Numbers:

SP845 SP745-NU-3-60-5 100-00831-06 SP845NL-3-L 100-00834-09 9-318-3C 93183C 100-00831-05 780-015 L0-15 LO15 LO-15 018-00080 50-204-01 018-00080 100-00834-42 1000083442 SP745-NU-3-60-5 780845 100-00831-06 100-00834 SP 845 SP845A 712-006 712-008 712-009 780-745 100-00831-01 780-015 780-845 SP845A 5H73696 SP845 100-00831-04 LB58807D 100-00831-52 100-00626-02 5H73325B 100-00826-02 100-00834-14 100-00834-05 SP845N0-3L SP100-00834-31 100-00831-07 SP 745 NL 1 60 SP745NL160 100-00831-13 780-745 SP745NU-3-60-5 100-00831-01 100-00831-62 780-5 NL-3-60 CAR5H73696 CARL39203 CAR780845.

Used in Lennox Furnace Models:

G12D2E-82-8.

Used in Enerco Heaters:

JW100-199NED 4040LA-5.

Used in Modine Heater Models:name:

DJE200S PAE75AG

Used in Rheem Ruud Furnace Models:

RGLA-10EA-AR UGLA-10EA-AR WGLA-10EA-AR RGLA10EA-AR UGLA10EA-AR WGLA10EA-AR

Used In Equipment Model Numbers:
AMPT65100

MODULE OPERATION:

Robertshaw Module Intermittent Ignition Control Provides 90 seconds of Spark followed by a 6-minute time delay purge between Ignition attempts.

After 3 tries, if no spark pilot flame is sensed, the control experience a 1 hour louckout. This allows the system to dissipate any gas build-up,making this universal module compatible with both natural gas and L.P. gas furnaces.

TECHNICAL:

INPUT POWER:24VAC.
HZ:50/60.
SPARK GAP: 7/64
TH CURRENT=.250AMP
PV + MV AT 24 VAC PV OR MV LOAD MAX = 1.5 AMP AT .5 PF.

** Most All Solid State Modules are not Field Repairable **