Modernization Electronic Ignition Kit. (Used to Upgrade Older Model Furnaces) Natural Gas or L.P. Ga

Modernization Electronic Ignition Kit. (Used to Upgrade Older Model Furnaces) Natural Gas or L.P. Ga
Code: GSV610U3003A
Price: $298.90
Quantity in Basket: None
Quantity:
VERY IMPORTANT NOTE!!! NOT FOR USE WITH DIRECT VENT OR MOBILE HOME SYSTEMS!!!

Modernization Upgraded Kit used to replace obsolete Gas Controls.

Used to Upgrade Furnaces and Boilers

Honeywell Relight Ignition Upgraded Replacement KIT:

Y8610U Universal Retrofit Intermittent Pilot Gas Burner Ignition System Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 Vac gas-fired atmospheric furnaces, boiler and heating appliances.

INLET GAS LINE SIZE: 3/4" or 1/2"

OUTLET GAS LINE SIZE:3/4" or 1/2"
Used Existing Pilot Light
Gas Pipe Reducing Bushings Included.

Honeywell Y8610U kits are for use with Natural or LP Gas: provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated.
Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed.

Replaces these Obsolete Furnaces Models with outdated parts no longer available from the original manufacture:Rheem RGEC-04NACR.

Product Specifications:

Ignition System Type Intermittent Pilot.
Ignition Sequence Continuous retry [after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot.
ignition takes place] Flame Sense Single Rod Ignition Source Internal high voltage spark generator Prepurge (sec) none.
Flame Failure Response Time (sec) 0.8 sec @ 1.0 microamp.
Typical Ignition Hardware Q345, Q3451.
Typical Gas Control VR8304M Dual Valve Combination Gas Control.
Gas Type L.P./ Natural
Description Provide electronic control of intermittent pilot ignition systems used on gas fired furnaces, boilers, and other heating appliances.
Dimensions (in.) 3 15/16 in. high, 5 7/16 in. wide, 2 5/8 in. deep.
Dimensions (mm) 100 mm high, 138 mm wide, 67 mm deep.
Control Voltage (Thermostat or other call for heat) 24 VAC / 60 Hz.
Electrical Ratings (Vac) 24 Vac.
Frequency (Hz) 60 Hz
Temperature Ratings (max. ambient)(C) -40 C to +74 C.
24 volt spark ignition gas valve kit
Temperature Ratings (max. ambient)(F) -40 F to +165 F.

Replaces Gas Valves in Lennox Furnace Models:

G11-110 G12D-110-4 G12D1104 G50RBG-3 EF33C2189 G11Q3E-137V-6 G11Q3E-137-V-6 G12Q4E-110-4 G12Q4E-SERIES G12Q5E-1659 G12Q4E-137-14 G12Q4E-Series G12Q3E-110-6.

**NOTE** THIS MODERNIZATION KIT DOES NOT COME WITH THE PILOT ASSEMBLY! IN MOST CASES YOU WILL USE YOUR OWN PILOT. IF YOU NEED A PILOT ORDER A UNIVERSAL PILOT FOR MOST MODELS PART NUMBER PIL9962H LOCATED AT THE BOTTOM OF THIS PAGE! **

24V Mercury Element with Pilot Gas Relay Operator Bimetal 2nd Stage Regulator Non-Adjustable
1585938 1585967 1585-967 1585967 1585968 36C93-301 36C93301 Suggested Replacement: None Upgrade to a Modernization Electronic Ignition Kit

5059-122 36C76-224 36C76224 30A48-1 36CBA-201 36C84-202 30A48-5.

Replaces Obsolete Robertshaw Gas Valves:

7000BKER-S7B 7100DER-S7A.

Replaces Obsolete Gas Controls in Dayton, Rheem, Ruud Furnaces:

3E377 HC802421C RGAA-05KCD UGAA-05KCD WGAA-05KCD RGAA05KCD UGAA05KCD WGAA05KCD RGAA-050AA UGAA-050AA WGAA-050AA RGAA050AA UGAA050AA WGAA050AA 48DC004 RGDA-06KC-ER UGDA-06KC-ER WGDA-06KC-ER RCAC12KA RGAA-14KA UGAA-14KA WGAA-14KA WGDC-12EC-JS UGDC-12EC-JS RGDC-12EC-JS RRGG-05E30JKR WRGG-05E30JKR URGG-05E30JKR RRGG05E30JKR WRGG05E30JKR URGG05E30JKR Z10-URG-05E30JKR-01R.

Replaces Coleman, York Obsolete Ignition Modules in Furnace Moddels:

D8SA060N16025A D8SA60N16020A CGH050 CGH0100 CGH125 CGH07512D.

Upgrade Furnace Brands: Gaffers & Sattler:

ACD-U 80-1 ACD 13-UBO-4.

Used to up graded Older Model Furnaces:

BLU080E942B1 BKU080E942B1 36/80YAC108TC DMS4-275-350 L5A112C16-1 HEHB120 867.763334 GWF100A012AIN R100D0N201 HSC400-6-S-2


Replaces Gas Valve and Ignition Module Part Numbers:



Used to Relace Obsolete Furnace Models:

400DVI UBS65-94 UCF175-55 GPH-80 G12Q3-82-4 100HCDAC TDN090A GSE50DN-3 BGLD100CB01.

Used to Upgraded Boilers: 36C98 Type

Replaces Obsolete Gas Valve Part Numbers:

P233500 P216600 8-2955D V400M1357 73A5601 13H4501 39C84-235 36D24-401 Q362A1011 Q361A1013 Q361A1005 507356 36C93-301 3046-25 36D13-405 3093-111 3093111 S9301A1001 G60PAG-1 525-32571-000 VR852M1005 Y8610U3003 25G53 25G53A404 25G53A-404 25G53-404 LO-15 3056-2 L0-15 RO198384 25C46-204 3098-151 R0198384 R0198575 R0198575 Y8610 V8800A1071 Y8610U SX613-300 P9661209F 300844 3049-537 36C84-220 FS-1 8D48A-702 77402 CAR5E757 CARY8610U3003.

S8610U Intermittent Pilot Module.
— VR8204 Intermittent Pilot Dual Valve Combination Gas Control with an ON-OFF manual valve, pressure regulator and two automatic main gas valve operators. Includes reducer bushings.
— 393691 LP Gas Conversion Kit.
— 392431 Igniter-Sensor Assembly. Includes ceramic-insulated Kanthal rod that attaches to the existing pilot burner in place of the thermocouple.
— 394800-30 Ignition Cable. 30 in. [762 mm] cable with connectors.
— 393690-14 Flange Assembly. Includes 3/4 in. straight flange with O-ring, 9/64 hex screws and wrench.
— Wiring Harness. 30 in. [762 mm] wiring harness with 1/4 in. quick-connect terminals.
— Reducer bushings for gas control.
— Adhesive mounting tape for S8610U module.
—Miscellaneous installation hardware – screws, solderless connectors, ground rod and adapter.
ELECTRICAL RATINGS:Voltage and Frequency – 24 VAC (nominal), 60 Hz. Current Rating – 0.7A (includes both module and gas control).
THERMOSTAT HEAT ANTICIPATOR SETTING – 0.7A plus current ratings of other devices in thermostat control circuit.
Compatible with all open-close switch type 24 VAC thermostats capable of supplying rated voltage and current to the module.
Also compatible with Honeywell electronic thermostats that directly switch the ignition module.
NEW PILOT OPTIONAL:

OPTIONAL PARTS LISTED BELOW